The NEW Temprecord Logger - "Mon-T"
New Temprecord logger - fully programmable
PLEASE NOTE - NEW SOFTWARE IS REQUIRED FOR THIS LOGGER - CLICK HERE TO DOWNLOAD
Default programmed to:
1 Sample per hour
Upper Limit: 60°C
Lower Limit: -40°C
Start Delay: 30 minutes
Start Button: Enabled
Stop Button: Disabled
Loop Overwrite: Disabled
Full Specifications
Memory: 4.6 k
Sample Capacity: 4600 Samples Minimum
Sample period: Programmable between 2 second and 18 hours
Recording Duration: Minimum 1.14 hours up to 12 months
Start Delay: 2 second increments from 2 second to 18 hours (in Multiples of 2 seconds)
Start / Stop button: Optional – enabled/disabled via user-selectable parameter
Operating Temperature range of Data Logger: -25 ̊C to +60 ̊C, -13 ̊F to +140 ̊F
Temperature Accuracy: 0.5 ̊C at 0 ̊C, 1 ̊F at 32 ̊F. Configurable
Display Resolution: 0.01 ̊C, 0.01 ̊F
Alarm Status Indicator: Green LED (within limits) or Red LED (outside limits) flash after button pressed
Battery Type: Lithium Manganese Dioxide (1.0V)
Dimensions: L 77.5mm x W 73.5mm
Case Protection Rating: IP67 (NEMA 4X)
Warranty Period: 12 months on Data Logger (from date of purchase) & 12 months on battery
|